Insights, Financial models

Commercial solar and battery storage: how to work out the savings

Commercial solar and battery storage pays through the costs a site stops paying. How to model load, tariffs, demand charges, diesel and financing.

By Roman Cintula · · 4 min read

Solar panels at a modern photovoltaic installation

A solar farm earns money by selling electricity. A solar and battery system on a factory, warehouse, mall or hospital works differently, because its value is the cost the site no longer pays: grid energy it does not buy, demand charges it avoids and diesel it does not burn. That makes commercial solar and battery storage harder to assess than a power plant, since the answer depends on how the site uses power hour by hour and on the tariff it pays. This article covers how to work out the savings and how the financing choice changes who keeps them.

Start with the load, hour by hour

The first input is the site’s load profile, meaning how much power it draws in each hour of a typical day in each month. A cold store running around the clock, an office that peaks in the afternoon and a factory on two shifts will get different value from the same system. Interval data from the meter is the best source.

Solar output follows the sun, so the match between the two decides how much solar is used on site and how much is surplus. Surplus is worth far less than self-consumed power in most markets, because export is paid at a lower rate than the retail tariff, or not at all. A system sized on annual energy totals, without the hourly match, will usually overstate the savings.

Read the tariff properly

Commercial tariffs have several parts. Energy is often priced by time of use, with higher rates at peak hours. Many also carry a demand charge based on the highest power drawn in the billing period, which can be a large share of the bill. Solar reduces energy bought during the day, but it may do little for a demand peak that falls in the evening or on a cloudy day.

That is where a battery earns its place. It can discharge into the peak to cut the demand charge, shift solar into expensive evening hours and, where allowed, charge from cheap overnight power. Each of these uses the same limited capacity, so the model has to decide what the battery does in each hour and cannot count the same stored energy twice.

Outages and diesel

In markets with unreliable grids, many sites run diesel generators during outages, and some run on diesel all the time. Diesel power is expensive once fuel, maintenance and generator wear are counted, so displacing it is often the largest saving.

The calculation needs care. During an outage, the site is served by solar first, then the battery, then the generator. How much diesel is displaced depends on when outages happen and how long they last, and the generator usually still has to be there for long outages and bad weather. A model should show the diesel that remains as well as the diesel saved, because the generator’s fixed costs do not disappear.

Costs over the system’s life

Capital cost includes panels, inverters, batteries, mounting, electrical work, engineering and the installer’s margin. Where equipment is imported, freight, duty, value-added tax (VAT) and the exchange rate belong in the budget, since equipment is usually priced in United States (US) dollars.

Over a life of twenty years or more, solar output declines slowly, batteries lose capacity and need replacing at least once, and inverters wear out. Replacements bought in a weaker local currency cost more than the original equipment did. On the other side, grid tariffs and diesel prices usually rise, which increases the savings each year. Both sets of assumptions should be explicit.

Who pays, and who keeps the savings

There are four common structures. The site owner can pay cash, which gives the highest lifetime saving for those with the capital. A loan spreads the cost, and works when the savings exceed the repayments. Under a lease, a third party owns the system and the site pays a fixed rental. Under a power purchase agreement (PPA), a developer owns and operates the system and the site pays only for the power it uses, usually at a discount to the grid tariff.

Lease and PPA structures need no capital from the site, and they pass the performance risk to the developer, who keeps part of the savings in return. Comparing them means putting all four on the same basis: the customer’s net present value, internal rate of return and payback under each.

The developer has its own view. It needs the customer payments to cover its capital cost, operating costs and debt, with the returns and coverage ratios its lender expects. A deal only works if both sides of that calculation do.

Running the comparison

Launchwright’s commercial solar and battery model matches the site load against solar and a battery for a typical day of every month, hour by hour, against three starting points: a grid with backup diesel, diesel alone or a reliable grid. It handles time-of-use rates, demand charges, export rules and outages, itemizes capital cost in US dollars with exchange rates, and compares cash, loan, lease and PPA side by side from the customer’s view. The Due Diligence Edition adds the developer’s case with debt sized to a coverage ratio. It includes presets for Nigeria, South Africa, Pakistan, Kenya and the United States.

For utility-scale projects that sell power to the grid, see solar and battery storage project finance. For what a lender expects from any model, read what a lender-ready financial model looks like. Testing whether a project is worth developing is part of our strategy and project development work.

This article is general information, not investment, tax or engineering advice. Tariffs and export rules vary by utility, so confirm them for your site.